Coleman 2333850408 SJEW Electrical Cable Coleman 232860408 SJEW Electrical Cable Romex SIMpull 63948472 Type NM-B Building Wire
For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved. For hard usage applications in accordance with NEC. Flexible and tough jacket. Temperature range of -50 to 105 degrees C. Used for portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90 conductor. TPE insulation. UL62, UL1581 and CSA-C22.2 No.49 approved. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Barogation 547070408 Solid Sprinkler Cable Romex SIMpull 6/2NM-WGX125 Type NM-B Building Wire Coleman 233860408 SJEW Electrical Cord
Underground sprinkler system wire. 18/7 solid, 30 volts RMS max. Used for sprinkler control systems. Soft annealed solid copper per ASTM B3-90. Polyethylene insulation and jacket. 18 AWG bare copper. Cable consists of 7 bare copper insulated conductors with an overall outer jacket diameter of 0.268; UL listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Hard service thermoplastic insulated conductors and overall thermoplastic jacket. All elastomer construction. Conductor is soft annealed stranded copper per ASTM B3-90. Temperature range from -50 degrees Celsius to +105 degrees Celsius. For hard usage applications in accordance with NEC and for use with portable tools and lamps, pumps and portable farm equipment. Weather resistant. 300 volt - 250' spool. UL 62, UL1581, CSA-C22.2 No. 49.
Romex SIMpull 8/3NM-WGX125 Type NM-B Building Wire Southwire SEU Service Entrance Cable Coleman 232870408 SJEW Electrical Cord
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Cross-linked polyethylene (XLPE) insulation. Insulated conductors laid parallel with bare ground wires helically wound around core. Covered with a reinforced binder tape. Sunlight resistant gray PVC jacket. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius in wet or dry locations, 600 volt. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. For hard usage applications in accordance with NEC. Flexible and tough jacket. Temperature range of -50 to 105 degrees C. Used for portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90 conductor. TPE insulation. UL62, UL1581 and CSA-C22.2 No.49 approved.
Southwire 12/2X500 W/G Quartz Single Ended Electrical Wire Coleman 233870408 SJEW Electrical Cable Southwire SEU Service Entrance Cable Wire
Pump cable, type THW, thermoplastic (PVC) insulated, 600 volt. All wire insulated. For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire 2SOLX125BARE Solid Electrical Wire Romex SIMpull 8/2UF-W/GX125 Type UF-B Building Wire Coleman 233270408 SJEOOW Flexible Power Cord
Equipment and circuit grounding. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool.
Southwire 12/3X500 W/G Electrical Wire Romex SIMpull 6/3NM-WGX125 Type NM-B Building Wire Southwire SEU Service Entrance Cable Wire
Pump cable, type THW, thermoplastic (PVC) insulated, 600 volt. All wire insulated. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire SEU Service Entrance Cable Wire Romex SIMpull 63949272 Type NM Building Wire Coleman 233280408 SJEOOW Electrical Cord
Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool.
Romex SIMpull 6/2UF-W/GX125 Type UF-B Building Wire Coleman 233880408 SJEW Electrical Cable Coleman 223280408 SEOOW Electrical Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool.
Romex SIMpull 63950072 Type NM-B Building Wire Coleman 233896608 SJEW Electrical Cable Coleman 22329M408 SJEOOW Electrical Cable
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool.
Coleman 224280408 SEOOW Electrical Wire Southwire 55082415 Armored Cable Zenith AS110024C Speaker Wire
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool. Wire whip, 14/3 AWG. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier.
   
 