Home > ELECTRICAL > ROUGH ELECTRICAL > CONDUIT
Choose a sub category:
PLASTIC FLEXIBLE CONDUIT METAL FLEX CONDUIT
Sort By:
1
Carlon 12005-UPC Flexible Raceway Carlon 12007-UPC Flexible Raceway CONDUIT NON-MET FLEX 1/2 X 25
Designed for use with 90 degree Celsius conductors, the hand bendable conduit offers the safety of assured grounding. For 600 volt use in walls, floors and ceilings in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. UL Listed. Designed for use with 90 degree Celsius conductors, the hand bendable conduit offers the safety of assured grounding. For 600 volt use in walls, floors and ceilings in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. UL Listed. For the installation and protection of electrical conductors in circuits of 600 volts or less. Manufactured with a spiral of rigid PVC reinforcement imbedded within a flexible PVC wall. Impact and crush resistant, liquid tight and highly flexible. UV sunlight resistant jacket. Rated for temperature range of -30 to 80 degrees C , 60 degrees C Oil (-22 to +176, 140 degrees F Oil). UL Listed.
Thomas & Betts 150DRB Liquidtight Flexible/Non-Metallic Conduit Kit Southwire 55189401 Liquid Tight Flexible Whip Thomas & Betts 150ERB-UPC Liquidtight Flexible/Non-Metallic Conduit Kit
Contains everything necessary for complete installation including 6' conduit, two straight fittings and one 90 degree fitting. Totally non-metallic system provides assured grounding for safety. Non-conductive, non-corrosive. Easy to install. UL Listed components. Resistant to rust, cracks, and separation. Constructed with two different PVC materials. 600 volt stranded copper THHN/THWN conductors and UL Listed LFNC-B fittings. Twelve-inch wire leads are left exposed at each end. Green insulated copper grounding conductor. Intended for 208/240/480 volt. UL / CSA, complies with NEC Article 356. Contains everything necessary for complete installation including 6' conduit, two straight fittings and one 90 degree fitting. Totally non-metallic system provides assured grounding for safety. Non-conductive, non-corrosive. Easy to install. UL Listed components.
Southwire 55189301 Liquid Tight Flexible Whip Alflex FO3750050M Type RWA Reduced Wall Flexible Conduit Ultratite 55094321 Liquid Tight Flexible Conduit
Resistant to rust, cracks, and separation. Constructed with two different PVC materials. 600 volt stranded copper THHN/THWN conductors and UL Listed LFNC-B fittings. Twelve-inch wire leads are left exposed at each end. Green insulated copper grounding conductor. Intended for 208/240/480 volt. UL / CSA, complies with NEC Article 356. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. For the installation and protection of electrical conductors in circuits of 600 volts or less. Manufactured with a spiral of rigid PVC reinforcement imbedded within a flexible PVC wall. Impact and crush resistant, liquid tight and highly flexible. UV sunlight resistant jacket. Rated for temperature range of -30 to 80 degrees C , 60 degrees C Oil (-22 to +176, 140 degrees F Oil). UL Listed.
Alflex FO5000025M Type RWA Reduced Wall Flexible Conduit Alflex FO7500025M Type RWA Reduced Wall Flexible Conduit Southwire UO5000025M Liquid Tight Flexible Conduit
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound.
Alflex FO37501001 Type RWA Reduced Wall Flexible Conduit Carlon 15005-100 Liquid Tight Flexible Conduit Carlon 12007-100 Flexible Raceway
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Lightweight and extremely flexible. Abrasion, corrosion, crush and strain resistant. For use with 90 degree Celsius conductors. Cold, heat and sunlight resistant. Dimensions conform to industry standards permitting the use of standard liquid tight fittings. For temperature ranges of 10 to 125 degrees Fahrenheit. Has a hard PVC spiral completely surrounded by a flexible PVC jacket. Impervious to weather. Use for outdoor lighting, water processing and pollution control, marina wiring, greenhouse wiring and transformer connections. For moving machinery controls/motors and machine tools. Use on heating, cooling and ventilation wiring; mounts easily for air conditioning and heat pumps. UL Listed. Designed for use with 90 degree Celsius conductors, the hand bendable conduit offers the safety of assured grounding. For 600 volt use in walls, floors and ceilings in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. UL Listed.
Alflex FO5000050M Type RWA Reduced Wall Flexible Conduit Alflex FO7500050M Type RWA Reduced Wall Flexible Conduit Carlon 15007-100 Liquid Tight Flexible Conduit
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Lightweight and extremely flexible. Abrasion, corrosion, crush and strain resistant. For use with 90 degree Celsius conductors. Cold, heat and sunlight resistant. Dimensions conform to industry standards permitting the use of standard liquid tight fittings. For temperature ranges of 10 to 125 degrees Fahrenheit. Has a hard PVC spiral completely surrounded by a flexible PVC jacket. Impervious to weather. Use for outdoor lighting, water processing and pollution control, marina wiring, greenhouse wiring and transformer connections. For moving machinery controls/motors and machine tools. Use on heating, cooling and ventilation wiring; mounts easily for air conditioning and heat pumps. UL Listed.
Carlon 12005-200 Flexible Raceway Alflex FO75001001 Type RWA Reduced Wall Flexible Conduit Southwire UO7500025M Liquid Tight Flexible Conduit
Designed for use with 90 degree Celsius conductors, the hand bendable conduit offers the safety of assured grounding. For 600 volt use in walls, floors and ceilings in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. UL Listed. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound.
Southwire UO5000050M Liquid Tight Flexible Conduit Alflex FO50001001 Type RWA Reduced Wall Flexible Conduit Southwire UO7500050M Liquid Tight Flexible Conduit
Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound.
Carlon 15008-100 Liquid Tight Flexible Conduit Carlon 15011-050 Liquid Tight Flexible Conduit Southwire UO500001001 Liquid Tight Flexible Conduit
Lightweight and extremely flexible. Abrasion, corrosion, crush and strain resistant. For use with 90 degree Celsius conductors. Cold, heat and sunlight resistant. Dimensions conform to industry standards permitting the use of standard liquid tight fittings. For temperature ranges of 10 to 125 degrees Fahrenheit. Has a hard PVC spiral completely surrounded by a flexible PVC jacket. Impervious to weather. Use for outdoor lighting, water processing and pollution control, marina wiring, greenhouse wiring and transformer connections. For moving machinery controls/motors and machine tools. Use on heating, cooling and ventilation wiring; mounts easily for air conditioning and heat pumps. UL Listed. Lightweight and extremely flexible. Abrasion, corrosion, crush and strain resistant. For use with 90 degree Celsius conductors. Cold, heat and sunlight resistant. Dimensions conform to industry standards permitting the use of standard liquid tight fittings. For temperature ranges of 10 to 125 degrees Fahrenheit. Has a hard PVC spiral completely surrounded by a flexible PVC jacket. Impervious to weather. Use for outdoor lighting, water processing and pollution control, marina wiring, greenhouse wiring and transformer connections. For moving machinery controls/motors and machine tools. Use on heating, cooling and ventilation wiring; mounts easily for air conditioning and heat pumps. UL Listed. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound.
Southwire UO75001001 Liquid Tight Flexible Conduit
Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound.
   
 
1